22 and 18 AWG stranded (7x30 and 16x30) tinned copper conductorsm conductors cabled. PVC insulation. PVC jacket.
Specifications
| Temp Range, Operating | -20ºC To +80ºC |
|---|---|
| Temp Rating, UL | 80ºC (UL AWM Style 2576) |
| Capacitance | 54.000 |
| Capacitance (Metric) | 177.174 |
| Current, Max. Recomm. | 2.5 Amps per conductor @ 25ºC^5.6 Amps per conductor @ 25ºC |
| Voltage, Max. Operating | 150 V RMS (UL AWM Style 2576)^ 300 V RMS |
| SKU | B-8446-U500 |
| Manufacturer | Belden |
| AWM Specification | UL Style 2576 (150 V 80ºC) |
| CEC/C(UL) Specification | CMG |
| RoHS | Yes |
| EU CE Mark | Yes |
| NEC/(UL) Specification | CMG |
| Mfr. Part No | 8446 060U500 |
| Flame Test - UL Flame Test | UL1685 FT4 Loading |
| Weight | 21.5000 |
| Color | CHROME |
| Type | Non-Paired |
| Conductor Size (AWG) | 22^18 |
| Conductor Material | TC - Tinned Copper^TC - Tinned Copper |
| Number of Conductors | 4^2 |
| Conductor Stranding | 7x30^16x30 |
| Insulation Material | PVC - Polyvinyl Chloride^PVC - Polyvinyl Chloride |
| Insulation Wall Thickness | .010^.019 |
| Insulation Wall Thickness (Metric) | 0.254^0.4826 |
| Overall Nominal Diameter | 0.236 |
| Outer Jacket Wall Thickness | .032 |
| Outer Jacket Material | PVC - Polyvinyl Chloride |
| Outer Shield Material | Unshielded |
| Amount | u500 ea |
| Overall Cabling - Overall Nominal Diameter (Metric) | 5.9944 |
| Outer Jacket - Nom. Wall Thickness (Metric) | 0.8128 |