Multi-Conductor Cables
Interstate Wire Co. carries a full line of multi-conductor cables from leading manufacturers of high quality cable and wire products. A multi-conductor cable can be defined as any combination of insulated conductors that are not paired.
Applications of Muli-Conductor Wires
Multi-Conductor cable application is typically the most important consideration when determining which type of multi-conductor cable is best for your needs. As the premier distributor for multi-conductor wires and cables, we offer cable for use in various industries, such as:
- Computer
- Communications
- Medical
- Control equipment
Data transmission industries. Communication applications typically need a finer gauge multi-conductor cable, roughly 16 gauge and smaller. Used for other applications such as in surgical equipment and production robotics, multi-conductor wire provides reliable, high performance data and power transmission capabilities.
Features and Added Services of Our Multi-Conductor Wires
- A wide range of insulating and jacketing materials, including PVC and plastic polymers, for protection, cable flexibility, and long life.
- A variety of shielding configurations, to provide the necessary shielding from low noise protection for medical instrumentation to high temperature protection for aerospace applications and sterile environments.
- Gauge sizes ranging from 4 to 24 gauge
- A wide range of cable dimensions, from ultra miniature for medical equipment to large, heavy duty power for data transmission
- Compliance with UL, NEC and CEC standards
Interstate Wire also provides value-added services including cutting, striping, twisting and marking services for your cable. We also offer design services to provide you with the most effective solution to your cabling application.
-
-
-
-
-
-
-
Belden 8484 0601000 - 20 AWG - 4 C - 1000 EA - 200 V RMS - CHROME
4 CONDUCTORS. #20 AWG(7X#28BC). PVC INSULATION. PVC JACKET.1000 ea, CHROME- Mfr's Part No.: 8484 0601000
- IWC Item No.: B-8484-1000
-
Belden 85220 3681000 - 20 AWG - 2 C - 1000 FT - 300 V RMS - CLEAR/TRANSPARENT
20 AWG (7X28) TINNED COPPER CONDUCTORS. 1 PAIR. TEFZEL INSULATION. TEFZEL JACKET.1000 ft, CLEAR/TRANSPARENT- Mfr's Part No.: 85220 3681000
- IWC Item No.: B-85220-1000
-
-
Belden 8728 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2717) - CHROME
2 PAIRS INDIVIDUALLY SHIELDED 22 AWG (7X30) TINNED COPPER. POLYPROPYLENE INSULATED. CABLED ON COMMON AXIS. PVC JACKET1000 ea, CHROME- Mfr's Part No.: 8728 0601000
- IWC Item No.: B-8728-1000
-
Belden 8748 0601000 - 22 AWG - C - 1000 EA - 150 V (UL AWM Style 2576); 300 V RMS - CHROME
22 AWG (7x30) tinned copper. 9 pairs. PVC insulation. unshielded. PVC jacket.1000 ea, CHROME- Mfr's Part No.: 8748 0601000
- IWC Item No.: B-8748-1000
-
Belden 8760 0601000 - 18 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET1000 ea, CHROME- Mfr's Part No.: 8760 0601000
- IWC Item No.: B-8760-1000
-
Belden 8760 06010000 - 18 AWG - C - 10000 FT - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET10000 ft, CHROME- Mfr's Part No.: 8760 06010000
- IWC Item No.: B-8760-10000
-
Belden 8760 0602000 - 18 AWG - C - 2000 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET2000 ea, CHROME- Mfr's Part No.: 8760 0602000
- IWC Item No.: B-8760-2000
-
Belden 8760 060250 - 18 AWG - C - 250 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET250 ea, CHROME- Mfr's Part No.: 8760 060250
- IWC Item No.: B-8760-250
-
Belden 8760 060500 - 18 AWG - C - 500 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET500 ea, CHROME- Mfr's Part No.: 8760 060500
- IWC Item No.: B-8760-500
-
Belden 8760 0605000 - 18 AWG - C - 5000 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET5000 ea, CHROME- Mfr's Part No.: 8760 0605000
- IWC Item No.: B-8760-5000
-
Belden 8760 060U1000 - 18 AWG - C - U1000 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKETu1000 ea, CHROME- Mfr's Part No.: 8760 060U1000
- IWC Item No.: B-8760-U1000
-
Belden 8760 060U500 - 18 AWG - C - U500 EA - 300 V RMS (UL AWM Style 2092) - CHROME
18 AWG (16X30) TINNED COPPER. POLYETHYLENE INSULATION. TWISTED BELDFOIL SHIELDED PAIR. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8760 060U500
- IWC Item No.: B-8760-U500
-
-
-
-
Belden 8767 060U500 - 22 AWG - C - U500 EA - 300 V RMS (UL AWM Style 2464) - CHROME
22 AWG SOLID TINNED COPPER. PVC INSULATION. 3 SHIELDED PAIRS WITH OVERALL CHROME PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8767 060U500
- IWC Item No.: B-8767-U500
-
Belden 8768 060500 - 22 AWG - C - 500 EA - 300 V RMS (UL AWM Style 2464) - CHROME
22AWG SOLID TINNED COPPER. PVC INSULATION. 6 SHIELDED PAIRS WITH OVERALL CHROME PVC JACKET500 ea, CHROME- Mfr's Part No.: 8768 060500
- IWC Item No.: B-8768-500
-
-
-
-
Belden 87760 0021000 - 18 AWG - C - 1000 FT - 300 V RMS - RED
18 AWG (19X30) TINNED COPPER. 2 CONDUCTORS. FEP INSULATED. ALUMINUM/MYLAR SHIELDED (FOIL OUT PLUS 20 AWG DRAIN). FLUOROCOPOLYMER JACKETED1000 ft, RED- Mfr's Part No.: 87760 0021000
- IWC Item No.: B-87760-1000
-
-
-
-
-
Belden 8786 060500 - 24^22 AWG - 4^2 C - 500 EA - 300 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKET500 ea, CHROME- Mfr's Part No.: 8786 060500
- IWC Item No.: B-8786-500
-
Belden 8786 060U500 - 24^22 AWG - 4^2 C - U500 EA - 300 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8786 060U500
- IWC Item No.: B-8786-U500
-
Belden 8787 060500 - 24^22 AWG - 8^2 C - 500 EA - 350 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKET500 ea, CHROME- Mfr's Part No.: 8787 060500
- IWC Item No.: B-8787-500
-
Belden 8787 060U500 - 24^22 AWG - 8^2 C - U500 EA - 350 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8787 060U500
- IWC Item No.: B-8787-U500
-
Belden 8788 060500 - 22 AWG - 5 C - 500 EA - 300 V RMS - CHROME
22 AWG (7X30) TINNED COPPER. 5 CONDUCTOR CABLE 3 CONDUCTORS INDIVIDUALLY FOIL SHIELDED. PVC INSULATED AND PVC JACKET500 ea, CHROME- Mfr's Part No.: 8788 060500
- IWC Item No.: B-8788-500
-
Belden 88107 008500 - 24 AWG - 1 C - 500 FT - 300 V RMS - GRAY
24 AWG stranded (7x32) tinned copper. 7-1/2 pairs. Foam Fep Insulation. overall 100% Beldfoil shield + 24 AWG (7x32) tinned copper drain wire. fluorocopolymer Jacket.500 ft, GRAY- Mfr's Part No.: 88107 008500
- IWC Item No.: B-88107-500
-
-
-
-
Belden 88741 0021000 - 22 AWG - C - 1000 FT - 300 V RMS - RED
22 AWG (7x30) Tinned copper. 2 pairs. FEP insulation. FEP jacket.1000 ft, RED- Mfr's Part No.: 88741 0021000
- IWC Item No.: B-88741-1000
-
-
-
-
-
-
-
-
-
-
-
-
-
Belden 9265 0101000 - AWG - C - 1000 EA - 30 V RMS - BLACK
Siamese Type RG59/U Type Coax 22 AWG (7x30) Bare Copper with Beldfoil Aluminum-Polyester Shielded Twisted Pair 22 AWG (7x30) Tinned Copper.1000 ea, BLACK- Mfr's Part No.: 9265 0101000
- IWC Item No.: B-9265-1000
-
Belden 9331 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (PLTC^ CMG)^ 150 V RMS (ITC) - CHROME
300V POWER LIMITED TRAY CABLE - 6 PAIRS OF 22 AWG (7X30) TINNED COPPER. PVC INSULATION. INDIVIDUAL PAIR BELDFOIL SHIELD WITH 22 AWG (7X30)TINNED COPPER DRAIN WIRE PER PAIR. OVERALL PVC JACKET WITH A NYLON RIPCORD.1000 ea, CHROME- Mfr's Part No.: 9331 0601000
- IWC Item No.: B-9331-1000
-
Belden 9343 0101000 - 14 AWG - C - 1000 EA - 600 V RMS (NEC Type TC)^ 150 V RMS (NPLF) - BLACK
600 V Tray Cable - 2 Conductors Of 14 AWG (42X30) Tinned Copper. PVC/Nylon Insulation. Beldfoil Shield With 18 AWG Tinned Copper Drain Wire. PVC Jacket.1000 ea, BLACK- Mfr's Part No.: 9343 0101000
- IWC Item No.: B-9343-1000
-
-
-
-
-
-
-
-
-
-
Belden 9513 0601000 - 22 AWG - C - 1000 EA - 300 V RMS - CHROME
3 PAIR 22 AWG (7X#30) TINNED COPPER. PVC INSULATION. BELDFOIL SHIELD. 22 AWG (7 X #30) TINNED COPPER DRAIN. PVC JACKET WITH NYLON RIPCORD.1000 ea, CHROME- Mfr's Part No.: 9513 0601000
- IWC Item No.: B-9513-1000
-
Belden 9623 060500 - 14 AWG - 5 C - 500 EA - 600 V RMS - CHROME
14 AWG (19X27) Tinned Copper. 5 Conductor Unshielded Cable500 ea, CHROME- Mfr's Part No.: 9623 060500
- IWC Item No.: B-9623-500
-
Belden 9682 0601000 - 24 AWG - C - 1000 EA - 30 V RMS (UL AWM Style 2919); 300 V RMS - CHROME
24 AWG (7X32) TINNED COPPER. 6 POLYETHYLENE INSULATED TWISTED PAIRS. OVERALL BELDFOIL(R) TAPE SHIELD WITH A 24 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET1000 ea, CHROME- Mfr's Part No.: 9682 0601000
- IWC Item No.: B-9682-1000
-
Belden 9684 0601000 - 24 AWG - 1 C - 1000 EA - 30 V RMS (UL AWM Style 2919); 300 V RMS - CHROME
24 AWG (7X32)TINNED COPPER. 12 POLYETHYLENE INSULATED TWISTED PAIRS PLUS ONE POLYETHYLENE INSULATED SINGLE. OVERALL BELDFOIL(R) TAPE SHIELD WITH A 24 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET1000 ea, CHROME- Mfr's Part No.: 9684 0601000
- IWC Item No.: B-9684-1000
-
Belden 9712 3681000 - 22^22 AWG - 1^1 C - 1000 EA - 300 V RMS - CLEAR/TRANSPARENT
2 CONDUCTORS PARALLEL. 22 AWG (7X30) 1 CONDUCTOR BARE. 1 CONDUCTOR TINNED. INTEGRAL INSULATION. JACKET.1000 ea, CLEAR/TRANSPARENT- Mfr's Part No.: 9712 3681000
- IWC Item No.: B-9712-1000
-
Belden 9717 3681000 - 14^14 AWG - 1^1 C - 1000 EA - 300 V RMS - CLEAR/TRANSPARENT
2 CONDUCTORS PARALLEL. 14 AWG (19X27) 1 CONDUCTOR BARE. 1 CONDUCTOR TINNED. INTEGRAL INSULATION. JACKET.1000 ea, CLEAR/TRANSPARENT- Mfr's Part No.: 9717 3681000
- IWC Item No.: B-9717-1000
-
Belden 9718 3681000 - 12^12 AWG - 1^1 C - 1000 EA - 300 V RMS - CLEAR/TRANSPARENT
2 CONDUCTORS PARALLEL. 12 AWG (65X30) 1 CONDUCTOR BARE. 1 CONDUCTOR TINNED. INTEGRAL INSULATION. JACKET.1000 ea, CLEAR/TRANSPARENT- Mfr's Part No.: 9718 3681000
- IWC Item No.: B-9718-1000
-
Belden 9728 060500 - 24 AWG - C - 500 EA - 300 V RMS (UL AWM Style 2493) - CHROME
24 AWG stranded (7x32) tinned copper. 4 pairs individually shielded 100% Beldfoil + 24 AWG (7x32) tinned copper drain wire. Datalene insulated. PVC Jacket.500 ea, CHROME- Mfr's Part No.: 9728 060500
- IWC Item No.: B-9728-500
-
-
Belden 9772 060500 - 22 AWG - C - 500 EA - 300 V RMS - CHROME
12 TRIADS. EACH TRIPLET. 22 AWG (7X30) TINNED COPPER CONDUCTORS. POLYPROPYLENE INSULATED. ALUMINUM POLYESTER SHIELD WITH 22 AWG (7X30) TINNED COPPER DRAIN WIRE. PVC JACKET. OVERALL PVC JACKET.500 ea, CHROME- Mfr's Part No.: 9772 060500
- IWC Item No.: B-9772-500
-
-
-
-
-
Belden 9833 0601000 - 24 AWG - C - 1000 EA - 30 V RMS (UL AWM Style 2919)^ 300 V RMS (CM) - CHROME
24 AWG 7X32 TINNED COPPER. 7 POLYETHYLENE INSULATED TWISTED PAIRS. OVERALL BELDFOIL/BRAID SHIELD. CHROME PVC JACKET.1000 ea, CHROME- Mfr's Part No.: 9833 0601000
- IWC Item No.: B-9833-1000
-
-
-
-
-
Belden 9936 0601000 - 24 AWG - 15 C - 1000 EA - 30 V RMS (UL AWM Style 2919)^ 300 V RMS - CHROME
24 AWG (7x32) tinned copper. 15 conductors Datalene insulated. with an overall Beldfoil shield. a tinned copper braid shield. PVC jacket.1000 ea, CHROME- Mfr's Part No.: 9936 0601000
- IWC Item No.: B-9936-1000
-
Belden 9944 0601000 - 22 AWG - 8 C - 1000 EA - 300 V RMS (UL AWM Style 2464) - CHROME
22 AWG (7x30) tinned copper. 8 conductors. PVC insulation with an overall Beldfoil shield. a tinned copper braid shield. PVC jacket.1000 ea, CHROME- Mfr's Part No.: 9944 0601000
- IWC Item No.: B-9944-1000
-
Belden ABS Type Approved Fire Alarm Cable
Bare Copper Conductors. Silicone Insulation. Foil Shield. LSZH Jacket.
-
Belden Access Control Banana Peel® Cable
(3) Shielded Multi-Conductors and (1) Shielded Multi-Pair
-
Belden AES/EBU Digital Audio Cable, Multi-Pair Snake, Ind & Overall
Brilliance Broadcast Cables
-
Belden AES/EBU Digital Audio Cable, Multi-Pair Snake, Ind Shield
Brilliance Broadcast Cables
-
Belden AES/EBU Digital Audio Cable, Single- and Double-Pair
Brilliance Broadcast Cables
-
Belden Analog Multi-Pair Snake Cable, CMR Rated
Analog Multi-Pair Snake Cable. Individually Shielded and Jacketed Pairs.
-
Belden Analog Multi-Pair Snake Cable, Flexible CMR Rated
Analog Multi-Pair Snake Cable. Individually Shielded and Jacketed Pairs.
-
Belden Analog Multi-Pair Snake Cable, Flexible Low-Capacitance
Tinned Copper. Datalene® Insulation. Ind. Shielded and Jacketed Pairs. PVC Jacket.
-
Belden Antenna Rotor Control Cables
Tinned Copper Conductors. PVC Insulation. PVC Jacket. 80°C.
-
Belden Audio and Video Composite Camera Cable, SMPTE 311M HDTV
(4) or (2) Power Conductors. SM Fiber w/24 and 20 or 16 AWG.
-
Belden Audio Cable, Commercial Audio Systems, Shielded, Riser or CL3R
Bare Copper Conductors. PVC Insulation. Foil Shield. PVC Jacket.
-
Belden Audio, Control and Instrumentation Cable, Foil Shielded
Tinned Copper. Polypropylene or Polyethylene Insulation. PVC Jacket.
-
Belden Audio, Control and Instrumentation Cable, Foil Shielded, P
Plenum. FEP Insulation. 200°C.