Hook Up Wire & Lead Wire

Interstate Wire Co. is the premier distributor of top quality hook-up wire and lead wire. Used in a broad range of applications hook-up wire must meet stringent industry, military, and government standards for interconnection circuits, electrical harness fabrications, and internal wiring.


Whether you are using our hook-up wire and lead wire in a household product, or in a sophisticated electronic application, Interstate Wire products will perform consistently at the highest level.

Hook Up & Lead Wire Features

  • Conductors constructed of bare copper, tinned copper, silver-plated copper, and nickel-plated copper. We offer a range of voltage ratings.
  • Insulation in a wide range of materials, including PVC, PTFE, EPDM, Neoprene and Silicone Rubber, to provide the insulation best suited for your application.
  • Insulation materials are color-coded, for easy identification and increased safety.
  • Compliance with the strictest UL, CSA and Mil-spec standards for safety and reliable performance in your equipment.
  • Available in a variety of sizes & designs, to meet the needs for different applications.
  • Consistent, reliable quality

Interstate Wire will also strip, twist, or cut the wire upon request to customize your order. We also offer custom design services to provide you with the most effective solution for your wiring application.


 

Items 101 to 200 of 254 total

Page:
  1. 1
  2. 2
  3. 3
  1. UL 1426 Battery Cable from Interstate Wire

    IWC UL 1426 (BC-5W2), Battery Cable, 1/0 AWG

    Battery Cable is made with Type 3 annealed fine stranded tinned copper, ASTM B172 Class K. Insulated with a PVC jacket for a durable yet flexible product that is resistant to gasoline, moisture, acid, alkali, abrasion and flame. This UL 1426 (BC-5W2) product meets CSA, SAE, USCG, ABYC and NMMA requirements.

  2. UL 1426 Battery Cable from Interstate Wire

    IWC UL 1426 (BC-5W2), Battery Cable, 2/0 AWG

    Battery Cable is made with Type 3 annealed fine stranded tinned copper, ASTM B172 Class K. Insulated with a PVC jacket for a durable yet flexible product that is resistant to gasoline, moisture, acid, alkali, abrasion and flame. This UL 1426 (BC-5W2) product meets CSA, SAE, USCG, ABYC and NMMA requirements.

  3. UL 1426 Battery Cable from Interstate Wire

    IWC UL 1426 (BC-5W2), Battery Cable, 3/0 AWG

    Battery Cable is made with Type 3 annealed fine stranded tinned copper, ASTM B172 Class K. Insulated with a PVC jacket for a durable yet flexible product that is resistant to gasoline, moisture, acid, alkali, abrasion and flame. This UL 1426 (BC-5W2) product meets CSA, SAE, USCG, ABYC and NMMA requirements.

  4. UL 1426 Battery Cable from Interstate Wire

    IWC UL 1426 (BC-5W2), Battery Cable, 4/0 AWG

    Battery Cable is made with Type 3 annealed fine stranded tinned copper, ASTM B172 Class K. Insulated with a PVC jacket for a durable yet flexible product that is resistant to gasoline, moisture, acid, alkali, abrasion and flame. This UL 1426 (BC-5W2) product meets CSA, SAE, USCG, ABYC and NMMA requirements.

  5. IWC UL AMW Style 10070 Extra Flexible PVC

    IWC UL AMW Style 10070 Extra Flexible PVC

    Tinned Copper Conductor. PVC Insulation. 105°C. 600V.

  6. IWC UL AWM Style 1330

    IWC UL AWM Style 1330

    Tinned or Nickel Coated Copper Conductor. Extruded FEP Insulation. 200°C. 600V.

  7. IWC UL AWM Style 1534, 14 AWG

    IWC UL AWM Style 1534, 14 AWG

    Tinned Copper Conductor. Irradiated PVC Insulation. 80°C. 150V.

  8. IWC UL AWM Style 1716

    IWC UL AWM Style 1716

    Tinned Plated Copper Conductor. Fluoropolymer Insulation. 150°C. 300V.

  9. IWC UL AWM Style 3239, XLPE, 5kV-40kV

    IWC UL AWM Style 3239, XLPE, 5kV-40kV

    Stranded Tinned Copper with Tinned Overcoat (TOC) or Stranded Bare Copper with Tinned Overcoat (TPC) - Irradiated Cross-linked Polyethylene

  10. IWC UL AWM Style 3257

    IWC UL AWM Style 3257

    Nickel Plated Copper. Silicone Rubber Blended w/ Red Iron Oxide. 250ºC. 25kV.

  11. IWC UL AWM Style 3266

    IWC UL AWM Style 3266

    Tinned Copper. Irradiated Cross-Linked Polyethylene (XLPE). 125ºC. 300V.

  12. IWC UL-AWM-1198-1199

    IWC UL-AWM-1198-1199

    Silver Plated Copper Conductor. PTFE. 150ºC (UL 1198), 200ºC (UL 1199). 300V.

  13. IWC UL-AWM-Style-1180

    IWC UL-AWM-Style-1180

    Silver Plated Copper Conductor. PTFE Insulation. 1/64" Minimum Wall. 200ºC. 300V.

  14. IWC UL-AWM-Style-1199

    IWC UL-AWM-Style-1199

    Heavy Wall. Silver Plated Copper. PTFE 1/32" Min. Avg Wall. 200ºC. 600V.

  15. IWC UL-AWM-Style-1431

    IWC UL-AWM-Style-1431

    Tinned Copper Conductor. Irradiated PVC Insulation. 105°C. 600V.

  16. IWC UL-AWM-Style-1536

    IWC UL-AWM-Style-1536

    Tinned Copper Conductor. Irradiated PVC Insulation. 80ºC.

  17. IWC UL-AWM-Style-3265

    IWC UL-AWM-Style-3265

    Tinned Copper Conductor. Cross-Linked Polyethylene (XLPE). 150ºC. 600V.

  18. IWC UL-Type-SIS-Wire-VW-1

    IWC UL-Type-SIS-Wire-VW-1

    Tinned Copper Conductor. Cross-Linked Polyethylene (XLPE). 90°C. 600V.

  19. Mil-Spec Hook-up/Lead Wire - 16 AWG - PVC - Polyvinyl Chloride Outer Jacket - ORANGE

    16 AWG Stranded Tinned Copper - PVC Insulated
    1000 ea, ORANGE
    • Mfr's Part No.: 8521 0031000
    • IWC Item No.: B-8521-3-1000
  20. Mil-Spec Hook-up/Lead Wire - 16 AWG - PVC - Polyvinyl Chloride Outer Jacket - YELLOW

    16 AWG Stranded Tinned Copper - PVC Insulated
    1000 ea, YELLOW
    • Mfr's Part No.: 8521 0041000
    • IWC Item No.: B-8521-4-1000
  21. Mil-Spec Hook-up/Lead Wire - 22 AWG - PVC - Polyvinyl Chloride Outer Jacket - BROWN

    22 AWG Stranded Tinned Copper - PVC Insulated
    100 ea, BROWN
    • Mfr's Part No.: 8503 001100
    • IWC Item No.: B-8503-1-100
  22. Mil-Spec Hook-up/Lead Wire - 22 AWG - PVC - Polyvinyl Chloride Outer Jacket - VIOLET

    22 AWG Stranded Tinned Copper - PVC Insulated
    1000 ea, VIOLET
    • Mfr's Part No.: 8503 0071000
    • IWC Item No.: B-8503-7-1000
  23. Mil-Spec Hook-up/Lead Wire - 22 AWG - PVC - Polyvinyl Chloride Outer Jacket - WHITE

    22 AWG Stranded Tinned Copper - PVC Insulated
    100 ea, WHITE
    • Mfr's Part No.: 8503 009100
    • IWC Item No.: B-8503-9-100
  24. Mil-Spec Hook-up/Lead Wire - 26 AWG - PVC - Polyvinyl Chloride Outer Jacket - BLUE/LIGHT

    26 AWG Stranded Tinned Copper - PVC Insulated
    1000 ea, BLUE/LIGHT
    • Mfr's Part No.: 8505 0061000
    • IWC Item No.: B-8505-6-1000
  25. MIL-W-16878/1 (M16878/1) Type B : 14 AWG

    MIL-W-16878/1 (M16878/1) Type B : 14 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  26. MIL-W-16878/1 (M16878/1) Type B : 16 AWG

    MIL-W-16878/1 (M16878/1) Type B : 16 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  27. MIL-W-16878/1 (M16878/1) Type B : 18 AWG

    MIL-W-16878/1 (M16878/1) Type B : 18 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  28. MIL-W-16878/1 (M16878/1) Type B : 20 AWG

    MIL-W-16878/1 (M16878/1) Type B : 20 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  29. MIL-W-16878/1 (M16878/1) Type B : 22 AWG

    MIL-W-16878/1 (M16878/1) Type B : 22 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  30. MIL-W-16878/1 (M16878/1) Type B : 24 AWG

    MIL-W-16878/1 (M16878/1) Type B : 24 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  31. MIL-W-16878/1 (M16878/1) Type B : 26 AWG

    MIL-W-16878/1 (M16878/1) Type B : 26 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  32. MIL-W-16878/1 (M16878/1) Type B : 28 AWG

    MIL-W-16878/1 (M16878/1) Type B : 28 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  33. MIL-W-16878/1 (M16878/1) Type B : 30 AWG and 32 AWG

    MIL-W-16878/1 (M16878/1) Type B : 30 AWG and 32 AWG

    Tinned Copper Conductor. PVC Insulation. .010" Nominal Wall. 105ºC. 600V.

  34. MIL-W-16878/1 (M16878/1) Type B and UL 1429 - Alpha

    MIL-W-16878/1 (M16878/1) Type B and UL 1429 - Alpha

    Tinned Copper Conductor. Irradiated PVC Insulation. 105°C. 600V (Type B). 150V (UL 1429).

  35. MIL-W-16878/11 (M16878/11) Type K

    MIL-W-16878/11 (M16878/11) Type K

    Silver Coated Copper Conductor. Extruded FEP Insulation. 200°C. 600V.

  36. MIL-W-16878/17 (M16878/17) Type BN

    MIL-W-16878/17 (M16878/17) Type BN

    Tinned Copper Conductor. PVC Insulation w/ Nylon. .010" Nominal Wall. 105ºC. 600V.

  37. MIL-W-16878/18 (M16878/18) Type CN

    MIL-W-16878/18 (M16878/18) Type CN

    Tinned Copper Conductor. PVC w/ Nylon. .017" Nominal Wall. 105°C. 1000V.

  38. MIL-W-16878/19 (M16878/19) Type DN

    MIL-W-16878/19 (M16878/19) Type DN

    Tinned Copper Conductor. PVC w/ Nylon. .031" Nominal Wall. 105°C. 3000V.

  39. MIL-W-16878/2 (M16878/2) Type C

    MIL-W-16878/2 (M16878/2) Type C

    Tinned Copper Conductor. PVC Insulation. .015" Nominal Wall. 105ºC. 1000V.

  40. MIL-W-16878/3 (M16878/3) Type D

    MIL-W-16878/3 (M16878/3) Type D

    Tinned Copper Conductor. PVC Insulation. .030" Nominal Wall. 105°C. 3000V.

  41. MIL-W-16878/4 (M16878/4) NEMA HP3 Type E : 10 - 14 AWG

    MIL-W-16878/4 (M16878/4) NEMA HP3 Type E : 10 - 14 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 600V.

  42. MIL-W-16878/4 (M16878/4) NEMA HP3 Type E : 32 AWG

    MIL-W-16878/4 (M16878/4) NEMA HP3 Type E : 32 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 600V.

  43. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Alpha), UL 1371 (Belden) : 18 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Alpha), UL 1371 (Belden) : 18 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  44. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 20 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 20 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  45. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 22 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 22 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  46. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 24 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 24 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  47. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 26 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 26 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  48. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 28 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 28 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  49. MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 30 AWG

    MIL-W-16878/4 (M16878/4) Type E, UL 1213 (Belden, Alpha) : 30 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  50. MIL-W-16878/4 (Type E), UL 1213 (Alpha), UL 1371 (Belden) : 16 AWG

    MIL-W-16878/4 (Type E), UL 1213 (Alpha), UL 1371 (Belden) : 16 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105° (UL). 600V.

  51. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3 : 26 AWG - 30 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3 : 26 AWG - 30 AWG

    Silver Plated Copper Conductor. PTFE Insulation. .015" Nominal Wall. 200ºC. 1000V.

  52. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3 : 8 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3 : 8 AWG

    Silver Plated Copper Conductor. PTFE Insulation. .015" Nominal Wall. 200ºC. 1000V.

  53. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Alpha) : 10 AWG - 14 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Alpha) : 10 AWG - 14 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  54. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 16 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 16 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  55. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 18 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 18 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  56. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 20 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 20 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  57. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 22 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 22 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  58. MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 24 AWG

    MIL-W-16878/5 (M16878/5) Type EE NEMA HP3, UL 1180 (Belden, Alpha) : 24 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 1000V (MIL). 300V (UL).

  59. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3 : 20 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3 : 20 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC. 250V.

  60. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 22 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 22 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  61. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 24 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 24 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  62. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 26 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 26 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  63. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 28 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 28 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  64. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 30 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 30 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  65. MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 32 AWG

    MIL-W-16878/6 (M16878/6) Type ET NEMA HP3, UL 1371 (Belden) : 32 AWG

    Silver Plated Copper Conductor. PTFE Insulation. 200ºC (MIL). 105ºC (UL). 250V.

  66. MIL-W-22759/11 (M22759/11) : 14 AWG - 18 AWG

    MIL-W-22759/11 (M22759/11) : 14 AWG - 18 AWG

    Standard Wall. Silver Plated Copper Conductor. PTFE. .010" Nom. Wall. 200ºC. 600V.

  67. MIL-W-22759/11 (M22759/11) : 20 AWG - 22 AWG

    MIL-W-22759/11 (M22759/11) : 20 AWG - 22 AWG

    Standard Wall. Silver Plated Copper Conductor. PTFE. .010" Nom. Wall. 200ºC. 600V.

  68. MIL-W-22759/11 (M22759/11) : 24 AWG - 28 AWG

    MIL-W-22759/11 (M22759/11) : 24 AWG - 28 AWG

    Standard Wall. Silver Plated Copper Conductor. PTFE. .010" Nom. Wall. 200ºC. 600V.

  69. MIL-W-22759/11 (M22759/11) : 8 AWG - 12 AWG

    MIL-W-22759/11 (M22759/11) : 8 AWG - 12 AWG

    Standard Wall. Silver Plated Copper Conductor. PTFE. .010" Nom. Wall. 200ºC. 600V.

  70. MIL-W-22759/12 (M22759/12)

    MIL-W-22759/12 (M22759/12)

    Standard Wall. Nickel Plated Copper Conductor. PTFE .010" Nom. Wall. 260ºC. 600V.

  71. MIL-W-22759/16 (M22759/16) : 14 - 16 AWG

    MIL-W-22759/16 (M22759/16) : 14 - 16 AWG

    14 & 16 AWG. Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  72. MIL-W-22759/16 (M22759/16) : 18 - 20 AWG

    MIL-W-22759/16 (M22759/16) : 18 - 20 AWG

    18 & 20 AWG. Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  73. MIL-W-22759/16 (M22759/16) : 2/0 - 12 AWG

    MIL-W-22759/16 (M22759/16) : 2/0 - 12 AWG

    2/0 - 12 AWG. Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  74. MIL-W-22759/16 (M22759/16) : 22 - 24 AWG

    MIL-W-22759/16 (M22759/16) : 22 - 24 AWG

    22 & 24 AWG. Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  75. MIL-W-22759/18 (M22759/18)

    MIL-W-22759/18 (M22759/18)

    Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  76. MIL-W-22759/19 (M22759/19)

    MIL-W-22759/19 (M22759/19)

    Silver Plated High-Strength Copper Alloy. ETFE Insulation. 150ºC. 600V.

  77. MIL-W-22759/22 (M22759/22)

    MIL-W-22759/22 (M22759/22)

    Silver Plated Copper Alloy Conductor. PTFE .010" Nominal Wall. 200ºC. 600V.

  78. MIL-W-22759/32 (M22759/32)

    MIL-W-22759/32 (M22759/32)

    Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  79. MIL-W-22759/33 (M22759/33)

    MIL-W-22759/33 (M22759/33)

    Silver Plated High Strength Copper Alloy Conductor. ETFE Insulation. 200ºC. 600V.

  80. MIL-W-22759/34 (M22759/34)

    MIL-W-22759/34 (M22759/34)

    Tinned Copper Conductor. ETFE Insulation. 150ºC. 600V.

  81. MIL-W-22759/35 (M22759/35) : Dual Insulation

    MIL-W-22759/35 (M22759/35) : Dual Insulation

    Silver Plated High Strength Copper Alloy. Cross-Linked ETFE. 200ºC. 600V.

  82. MIL-W-22759/41 (M22759/41)

    MIL-W-22759/41 (M22759/41)

    Nickel Plated Copper. Dual Layer XLETFE Copolymer. 200ºC. 600V.

  83. MIL-W-22759/43 (M22759/43)

    MIL-W-22759/43 (M22759/43)

    Stranded Silver Plated Copper. ETFE Insulation. 200ºC. 600V.

  84. MIL-W-22759/44 (M22759/44)

    MIL-W-22759/44 (M22759/44)

    Silver Plated Copper Conductor. ETFE Insulation. 200ºC. 600V.

  85. MIL-W-22759/8 (M22759/8)

    MIL-W-22759/8 (M22759/8)

    Medium Wall. Nickel Plated Copper Conductor. Mineral Filled PTFE. 260ºC. 600V.

  86. MIL-W-22759/9 (M22759/9)

    MIL-W-22759/9 (M22759/9)

    Medium Wall. Silver Plated Copper Conductor. PTFE .015" Nom. Wall. 200ºC. 1000V.

  87. MIL-W-25038/1 (M25038/1)

    MIL-W-25038/1 (M25038/1)

    27% Nickel-Coated Copper Conductor. Composite Inorganic Dielectric Insulation. PTFE Glass Braid or Fused PTFE Tape Wrapped Jacket. 260ºC. 600V.

  88. MIL-W-25038/3 (M25038/3)

    MIL-W-25038/3 (M25038/3)

    27% Nickel-Coated Copper Conductor. Composite Inorganic Dielectric Insulation. Fused PTFE Tape Wrapped Jacket. 260ºC. 600V.

  89. MIL-W-5086/1 (M5086/1)

    MIL-W-5086/1 (M5086/1)

    Tinned Copper Conductor. PVC Insulation with Nylon Jacket. 105°C. 600V.

  90. MIL-W-5086/2 (M5086/2)

    MIL-W-5086/2 (M5086/2)

    Tinned Copper Conductor. PVC + Glass Braid w/ Clear Nylon Jacket. 105°C. 600V.

  91. MIL-W-81044/12 (M81044/12) Lightweight Wall

    MIL-W-81044/12 (M81044/12) Lightweight Wall

    Tinned Copper Conductor. Cross-Linked Polyalkene Insulation. 150ºC. 600V.

  92. MIL-W-81044/9 (M81044/9) Medium Weight Wall

    MIL-W-81044/9 (M81044/9) Medium Weight Wall

    Tinned Copper Conductor. Cross-Linked Polyalkene Insulation. 150ºC. 600V.

  93. Shielding and Bonding Cable : Flat Braid

    Shielding and Bonding Cable : Flat Braid

    Tinned Copper Flat Braid.

  94. Shielding and Bonding Cable, Tubular Braid

    Shielding and Bonding Cable, Tubular Braid

    Tinned Copper Tubular Braid.

  95. Test Prod Wire

    Test Prod Wire

    Tinned Copper Conductor. Rubber Insulation.

  96. TFFN/TFN Fixture Wire, 16-18 AWG

    TFFN/TFN Fixture Wire, 16-18 AWG

    Bare Copper Conductor. PVC Insulation w/ Nylon Jacket. 90ºC. 600V.

  97. THHN Building Wire 500mcm-1 AWG

    THHN Building Wire 500mcm-1 AWG

    Bare Copper Conductor. PVC Insulation w/ Nylon Jacket. 90ºC. 600V.

  98. THHN Building Wire, 10-14 AWG

    THHN Building Wire, 10-14 AWG

    Bare Copper Conductor. PVC Insulation w/ Nylon Jacket. 90ºC. 600V.

  99. THHN Building Wire, 2-8 AWG

    THHN Building Wire, 2-8 AWG

    Bare Copper Conductor. PVC Insulation w/ Nylon Jacket. 90ºC. 600V.

  100. UL AWM Style 1007 and 1569, 14 AWG

    UL AWM Style 1007 and 1569, 14 AWG

    Tinned Copper Conductor. PVC Insulation. 80ºC (UL1007), 105ºC (UL1569). 300V.